Windows Installation Checklists

Task

 

With Access Logix

Without Access Logix

Reference Document

 

 

 

 

 

14

FC4500 Storage

Connect a computer to the serial

Connect a computer to the serial

Storage-system setup

 

System

port on the storage system.

port on the storage system

guide

 

Set properties for

From the computer connected to

From the computer connected to

Navisphere CLI

 

PowerPath

the storage system’s serial port,

the storage system’s serial port,

reference

 

 

 

 

use the following Navisphere CLI

use the following Navisphere CLI

 

 

 

commands to set the following

command to determine the

 

 

 

storage-system properties for the

default storage-system type:

 

 

 

server’s HBA or NIC ports

navicli -np -d device

 

 

 

(initiators):

 

 

 

systemtype

 

 

 

navicli -np -d device

 

 

 

where device is the name of the

 

 

 

storagegroup -sethost -host

 

 

 

computer port connected to the

 

 

 

servername -type 3

 

 

 

storage-system serial port (for

 

 

 

navicli -np -d device

 

 

 

example, com1).

 

 

 

storagegroup -sethost -host

If the default storage-system

 

 

 

servername -failovermode 1

 

 

 

system type is not 3 (CLARiiON

 

 

 

 

 

 

 

navicli -np -d device

Open), use the following

 

 

 

storagegroup -sethost -host

Navisphere CLI command to set

 

 

 

servername -arraycommpath 1

it to 3:

 

 

 

where

navicli -np -d device

 

 

 

device is the name of the

systemtype -config 3

 

 

 

 

 

 

 

computer port connected to the

CAUTION The above command

 

 

 

storage-system serial port (for

reboots both SPs at the same

 

 

 

example, com1).

time.

 

 

 

servername is the name of the

 

 

 

 

server with the HBAs.

 

 

 

 

 

From the computer connected to

 

 

 

 

the storage system’s serial port,

 

 

 

 

use the following Navisphere CLI

 

 

 

 

commands to set the following

 

 

 

 

default storage-system

 

 

 

 

properties:

 

 

 

 

navicli -np -d device

 

 

 

 

failovermode 1

 

 

 

 

navicli -np -d device

 

 

 

 

arraycommpath 1

 

 

 

 

where device is the name of the

 

 

 

 

computer port connected to the

 

 

 

 

storage-system serial port (for

 

 

 

 

example, com1).

 

 

 

 

 

 

15

Server

Use the Disk Management tool to

Use the Disk Management tool to

Windows documentation

 

Make target SPs

scan for disks.

scan for disks.

 

 

 

 

 

 

available

 

 

 

 

 

 

 

 