TABLE B-3Sun StorEdge T3+ Array SUNWsecfg Error Messages

Message

Description and Cause of Error

Suggested Action

 

 

 

Common to Sun

Present configuration does not match

Check the present Sun StorEdge T3+

StorEdge T3+ array

Reference configurations

array configuration with showt3 -n

 

 

 

<t3> command and verify whether

 

 

 

the configuration is corrupted or has

 

 

 

changed. If it is not one of the standard

 

 

 

configurations, restore the

 

 

 

configuration using the

 

 

 

restoret3config command.

 

 

 

 

Common to Sun

1.

Could not mount volume $vol.

There might be multiple drive failures

StorEdge T3+ array

2.

$lun config does not match

or corrupted data or parity on the

 

 

 

LUN. Replace the failed FRUs and

 

 

 

restore the Sun StorEdge T3+ array

 

 

 

configuration with the

 

 

 

restoret3config -f -n t3_name

 

 

 

command.

 

 

 

Common to Sun

The $fru status is not ready or

The disk, controller, or loop interface

StorEdge T3+ array

enabled. Operations on the Sun

card in the Sun StorEdge T3+ array

 

StorEdge T3+ array are being aborted.

might be bad. Replace the failed FRU

 

 

 

and rerun the utility.

 

 

 

 

Common to Sun

1.

The Sun StorEdge T3+ array is not

The Sun StorEdge T3 array

StorEdge T3+ array

 

of T3B type, and it cannot continue

configuration is not a standard

 

 

aborting operations.

configuration (refer to the t3

 

 

 

default/custom configuration table in

 

2.

t3config utilities are supported

the Sun StorEdge 3900 and 6900 Series

 

 

only in the Sun StorEdge T3+ array;

Hardware Installation and Service

 

 

the t3config utilities are not

Manual.)

 

 

supported on Sun StorEdge T3+

Use showt3 -n t3_name to display

 

 

arrays with 1.xx firmware.

the present configuration. Use the

 

 

 

modifyt3config and

 

 

 

restoret3config utility to

 

 

 

configure the Sun StorEdge T3+ array.

 

 

 

checkt3config

vol init command is being executed

Check whether any other secfg utility

 

by another user. Additional vol

is running. If one is running, allow it to

 

commands cannot run.

finish.

 

 

 

checkt3config

An error occurred while checking proc

Check whether any other secfg or

 

list, aborting operation on

native Sun StorEdge T3+ commands

 

$BRICK_IP{$brick_name}

are being executed on the particular

 

 

 

Sun StorEdge T3+ array.

 

 

 

 

Appendix B SUNWsecfg Error Messages 137

Page 153