8Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
Note that in the Class and State fields, the virtualization engines arepresented as
two primary/ONLINE devices. The current Sun StorEdge TrafficManager design
does not enable you to manually halt the I/O (that is, you cannot perform a failover
to the secondary path) when only primary devices are present.
Alternatives to Sun StorEdge Traffic Manager
As an alternative to using Sun StorEdge TrafficManager, you can manually halt the
I/O using one of two methods: quiesce I/O and unconfigure the c2 path. These
methods are explained below.

To Quiesce the I/O

1. Determine the path you want to disable.
2. Type:

To Unconfigure the c2 Path

1. Type:
# cfgadm -c unconfigure device
#cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 scsi-bus connected configured unknown
c0::dsk/c0t0d0 disk connected configured unknown
c0::dsk/c0t1d0 disk connected configured unknown
c1 scsi-bus connected configured unknown
c1::dsk/c1t6d0 CD-ROM connected configured unknown
c2 fc-fabric connected configured unknown
c2::210100e08b23fa25 unknown connected unconfiguredunknown
c2::2b000060220041f4 disk connected configured unknown
c3 fc-fabric connected configured unknown
c3::210100e08b230926 unknown connected unconfiguredunknown
c3::2b000060220041f9 disk connected configured unknown
c4 fc-private connected unconfiguredunknown
c5 fc connected unconfigured unknown