114 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
t3 ib Comm_Lost Down Y [ Info/Action ] Lost
communication
(InBandwithdiag213
(ip=xxx.20.67.21
3) ( last rebootwas
2001-09-27 15:22:00)
Information: InBand.
This event is
established using
luxadm. This
monitoring may not
be activated for a
particular Sun
StorEdge T3+ array.
Recommended action:
1. Verify luxadm via
command line
(luxadm probe,
luxadm display)
2. Verify cables,
GBICs and
connections along
data path.
3. Check the Storage
Automated
Diagnostic
EnvironmentSAN
TopologyGUI to
identify the failing
segment of the
data path.
4. Verify the correct
FC switch
configuration,if
applicable.
t3 oob Comm_Lost Down Y [ Info/Action ] Lost
communication
(OutOfBand with
diag213
(ip=xxx.20.67.212)
ProbableCause: This
problemcan also be
causedby a very slow
network, or because
the Ethernet
connectionto this Sun
StorEdge T3+ array
was lost.
Information:
OutOfBand. This
means that the Sun
StorEdge T3+ array
failed to answer to a
ping or failed to
returnits tokens.
Recommended action:
1. Check Ethernet
connectivity to the
affectedSun
StorEdge T3+
array.
2. Verify the Sun
StorEdgeT3+ array
is booted correctly.
3. Verify the correct
TCP/IPsettings on
the Sun StorEdge
T3+ array .
4. Increase the http
and/or ping
timeout in
Utilities--
>System--
>System--
>Timeouts. The
currentdefault
timeouts are10
seconds for ping
and 60 seconds for
http (tokens).
Category Component EventType Sev Action Description Information