Category

Component

EventType

Sev

Action

Description

Information

 

 

 

 

 

 

 

t3

ib

Comm_Lost

Down

Y

[ Info/Action ] Lost

Recommended action:

 

 

 

 

 

communication

1.

Verify luxadm via

 

 

 

 

 

(InBandwithdiag213

 

command line

 

 

 

 

 

(ip=xxx.20.67.21

 

(luxadm probe,

 

 

 

 

 

3) ( last reboot was

 

luxadm display)

 

 

 

 

 

2001-09-27 15:22:00)

2.

Verify cables,

 

 

 

 

 

 

 

GBICs and

 

 

 

 

 

 

 

connections along

 

 

 

 

 

Information: InBand.

 

data path.

 

 

 

 

 

This event is

3.

Check the Storage

 

 

 

 

 

established using

 

Automated

 

 

 

 

 

luxadm. This

 

Diagnostic

 

 

 

 

 

monitoring may not

 

Environment SAN

 

 

 

 

 

be activated for a

 

Topology GUI to

 

 

 

 

 

particular Sun

 

identify the failing

 

 

 

 

 

StorEdge T3+ array.

 

segment of the

 

 

 

 

 

 

 

data path.

 

 

 

 

 

 

4.

Verify the correct

 

 

 

 

 

 

 

FC switch

 

 

 

 

 

 

 

configuration, if

 

 

 

 

 

 

 

applicable.

 

 

 

 

 

 

 

t3

oob

Comm_Lost

Down

Y

[ Info/Action ] Lost

Recommended action:

 

 

 

 

 

communication

1.

Check Ethernet

 

 

 

 

 

(OutOfBand with

 

connectivity to the

 

 

 

 

 

diag213

 

affected Sun

 

 

 

 

 

(ip=xxx.20.67.212)

 

StorEdge T3+

 

 

 

 

 

 

 

array.

 

 

 

 

 

Probable Cause: This

2.

Verify the Sun

 

 

 

 

 

problem can also be

 

StorEdge T3+ array

 

 

 

 

 

caused by a very slow

 

is booted correctly.

 

 

 

 

 

network, or because

3.

Verify the correct

 

 

 

 

 

the Ethernet

 

TCP/IP settings on

 

 

 

 

 

connection to this Sun

 

the Sun StorEdge

 

 

 

 

 

StorEdge T3+ array

 

T3+ array .

 

 

 

 

 

was lost.

4.

Increase the http

 

 

 

 

 

 

 

and/or ping

 

 

 

 

 

Information:

 

timeout in

 

 

 

 

 

 

 

Utilities--

 

 

 

 

 

OutOfBand. This

 

>System--

 

 

 

 

 

means that the Sun

 

>System--

 

 

 

 

 

StorEdge T3+ array

 

>Timeouts. The

 

 

 

 

 

failed to answer to a

 

current default

 

 

 

 

 

ping or failed to

 

timeouts are 10

 

 

 

 

 

return its tokens.

 

seconds for ping

 

 

 

 

 

 

 

and 60 seconds for

 

 

 

 

 

 

 

http (tokens).

 

 

 

 

 

 

 

 

114 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 130
Image 130
Sun Microsystems 6900 Series, 3900 Series manual Luxadm probe