Category | Component | EventType | Sev | Action | Description | Information | |
|
|
|
|
|
|
| |
t3 | power. | Alarm- | Red | Y | [ Info/Action ] The | Information: The state | |
| output |
|
|
| state of | of the power in the | |
|
|
|
|
| power.u1pcu1.PowOu | Sun StorEdge T3+ | |
|
|
|
|
| tput on diag213 | array power cooling | |
|
|
|
|
| (ip=xxx.20.67.21 | unit is not optimal. | |
|
|
|
|
| 3) is Fault |
|
|
|
|
|
|
|
| Recommended action: | |
|
|
|
|
|
| 1. | Telnet to affected |
|
|
|
|
|
|
| Sun StorEdge T3+ |
|
|
|
|
|
|
| array. |
|
|
|
|
|
| 2. | Verify power |
|
|
|
|
|
|
| cooling unit state |
|
|
|
|
|
|
| in fru stat. |
|
|
|
|
|
| 3. | Replace PCU, if |
|
|
|
|
|
|
| necessary. |
|
|
|
|
|
|
| |
t3 | power.temp | Alarm- | Red | Y | [ Info/Action ] The | Information: The state | |
|
|
|
|
| state of | of the temperature in | |
|
|
|
|
| power.u1pcu1.PowT | the Sun StorEdge T3+ | |
|
|
|
|
| emp on diag213 | array power cooling | |
|
|
|
|
| (ip= | unit is either too high | |
|
|
|
|
| xxx.20.67.213) | or is unknown. | |
|
|
|
|
| is Fault |
|
|
|
|
|
|
|
| Recommended action: | |
|
|
|
|
|
| 1. | Telnet to the |
|
|
|
|
|
|
| affected Sun |
|
|
|
|
|
|
| StorEdge T3+ |
|
|
|
|
|
|
| array. |
|
|
|
|
|
| 2. | Verify that the |
|
|
|
|
|
|
| power cooling unit |
|
|
|
|
|
|
| state is in ‘fru stat’ |
|
|
|
|
|
| 3. Replace the PCU if | |
|
|
|
|
|
|
| necessary. |
|
|
|
|
|
|
| |
t3 | enclosure | Alarm.log | Red | Y | [ Info/Action ] | Information: This | |
|
|
|
|
| Errors(s) found in | event includes all | |
|
|
|
|
| logfile: /var/adm/ | important errors | |
|
|
|
|
| messages.t3 | found. | |
|
|
|
|
|
| Recommended action: | |
|
|
|
|
|
| Check the messages | |
|
|
|
|
|
| file for appropriate | |
|
|
|
|
|
| action. | |
|
|
|
|
|
|
|
|
112 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002