Site

:

FSDE LAB Broomfield CO

Source

:

diag.xxxxx.xxx.com

Severity :

Normal

 

Category :

Message

Key: message:diag.xxxxx.xxx.com

EventType:

LogEvent.driver.MPXIO_offline

EventTime:

01/08/2002 14:48:02

Found 2 ’driver.MPXIO_offline’ warning(s) in logfile: /var/adm/messages on diag.xxxxx.xxx.com (id=80fee746):

Jan 8 14:47:07

WWN:2b000060220041f9

diag.xxxxx.xxx.com mpxio: [ID

779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303053

(ssd19) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0

(fp1) to

target

address: 2b000060220041f9,1 is offline

Jan 8 14:47:07

WWN:2b000060220041f9

diag.xxxxx.xxx.com mpxio: [ID

779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303052

(ssd18) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0

(fp1) to

target address: 2b000060220041f9,0 is offline

 

FIGURE 3-2Data Host Notification of Severe Link Error

 

 

 

Site

: FSDE LAB Broomfield CO

 

Source

: diag.xxxxx.xxx.com

 

Severity

: Normal

 

 

Category

: Switch

Key: switch:100000c0dd0057bd

EventType: StateChangeEvent.X.port.6

 

EventTime: 01/08/2002 14:54:20

 

’port.6’ in SWITCH diag-sw1a (ip=192.168.0.30) is now Unknown (status- state changed from ’Online’ to ’Admin’):

FIGURE 3-3Storage Service Processor Notification

Note An A1/B1 FC link error can cause a port in sw1a or sw1b to change state.

24 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 40
Image 40
Sun Microsystems 6900 Series, 3900 Series manual 2Data Host Notification of Severe Link Error