Replacing the Master Midplane
Follow this procedure when replacing the master midplane in a Sun StorEdge T3+ array. This procedure is detailed in the Storage Automated Diagnostic Environment User’s Guide.
▼To Replace the Master Midplane
1.Choose Maintenance
Refer to Chapter 3 of the Storage Automated Diagnostic Environment User’s Guide.
2.In the Maintain Devices window, delete the device that is to be replaced.
3.Choose Maintenance
4.In the Device Discovery window, rediscover the device.
5.Choose Maintenance
a.Select the host that monitors the replaced FRU.
b.Click Create and Retrieve Selected Topologies.
c.Click Merge and Push Master Topology.
Conclusion
Any time a master midplane is replaced, you must rediscover the device using the procedure described above. This is especially important when the Storage Service Processor is replaced as a FRU, whether the Storage Service Processor is the master or the slave.