TABLE 6-1Storage Automated Diagnostic Environment Event Grid for Switches (Continued)

Cat

Component

EventType

Sev

Action

Description

Information/Action

 

 

 

 

 

 

 

switch

port

StateChange+

 

 

[ Info/Action ] port.1

Port on switch is

 

 

 

 

 

in SWITCH diag185

now available.

 

 

 

 

 

(ip=

 

 

 

 

 

 

 

xxx.20.67.185) is

 

 

 

 

 

 

 

now Available (status-

 

 

 

 

 

 

 

state changed from

 

 

 

 

 

 

 

OFFLINE to ONLINE)

 

 

 

 

 

 

 

 

 

switch

port

StateChange-

Red

Y

[ Info/Action ] port.1

Information: A port

 

 

 

 

 

in SWITCH diag185

on the switch has

 

 

 

 

 

(ip=xxx.20.67.185)

logged out of the

 

 

 

 

 

is now Not-Available

Fabric and has gone

 

 

 

 

 

(status state changed

offline.

 

 

 

 

 

from ONLINE to

 

 

 

 

 

 

 

OFFLINE)

Recommended

 

 

 

 

 

 

action:

 

 

 

 

 

 

1.

Verify cables,

 

 

 

 

 

 

 

GBICs, and

 

 

 

 

 

 

 

connections

 

 

 

 

 

 

 

along the Fibre

 

 

 

 

 

 

 

Channel path.

 

 

 

 

 

 

2.

Check Storage

 

 

 

 

 

 

 

Automated

 

 

 

 

 

 

 

Diagnostic

 

 

 

 

 

 

 

Environment

 

 

 

 

 

 

 

SAN Topology

 

 

 

 

 

 

 

GUI to identify

 

 

 

 

 

 

 

failing segment

 

 

 

 

 

 

 

of the data path.

 

 

 

 

 

 

3.

Verify the correct

 

 

 

 

 

 

 

FC switch

 

 

 

 

 

 

 

configuration.

 

 

 

 

 

 

 

switch

enclosure

Statistics

 

 

[ Info ] Statistics

Port Statistics

 

 

 

 

 

about switch d2-

 

 

 

 

 

 

 

swb1

 

 

 

 

 

 

 

(ipxxx.0.0.41)

 

 

 

 

 

 

 

10002000007a609

 

 

 

 

 

 

 

 

 

 

Chapter 6 Troubleshooting Sun StorEdge FC Switch-8 and Switch-16 Devices 67

For Internal Use Only

Page 83
Image 83