CODE EXAMPLE | Path marked “unusable” |
|
|
| |
|
|
|
|
|
|
# cfgadm |
|
|
|
|
|
Ap_Id | Type | Receptacle | Occupant | Condition | |
ac0:bank0 | memory | connected | configured | ok | |
ac0:bank1 | memory | empty | unconfigured unknown | ||
c1 | connected | configured |
| unknown | |
c16 | connected | unconfigured unknown | |||
c18 | connected | unconfigured unknown | |||
c19 | connected | unconfigured unknown | |||
c1::dsk/c1t6d0 |
| connected | configured |
| unknown |
c20 | connected | unconfigured unknown | |||
c21 | connected | configured |
| unknown | |
c21::50020f2300006355 | disk | connected | configured |
| unusable |
|
|
|
|
|
|
FRU tests available for the A4/B4 FC Link Segment
■The switchtest can only be run from the Storage Service Processor
■The linktest will be able to isolate the switch and the GBIC on the switch. It will not be able to isolate the cable or the Sun StorEdge T3+ array controller.
▼To Isolate the A4/B4 FC Link
1.Quiesce the I/O on the A4/B4 FC link path.
2.Run linktest from the Storage Automated Diagnostic Environment GUI to isolate suspected failing components.
Alternatively, follow these steps:
1.Quiesce the I/O on the A4/B4 FC link path.
2.Run switchtest to test the entire link
3.Break the connnection by uncabling the link.
4.Insert the loopback connector into the switch port.
44 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002