CODE EXAMPLE 3-8 Failed

Path marked “unusable”

 

 

 

 

 

 

 

 

 

# cfgadm -al

 

 

 

 

 

Ap_Id

Type

Receptacle

Occupant

Condition

ac0:bank0

memory

connected

configured

ok

ac0:bank1

memory

empty

unconfigured unknown

c1

scsi-bus

connected

configured

 

unknown

c16

scsi-bus

connected

unconfigured unknown

c18

scsi-bus

connected

unconfigured unknown

c19

scsi-bus

connected

unconfigured unknown

c1::dsk/c1t6d0

CD-ROM

connected

configured

 

unknown

c20

fc-private

connected

unconfigured unknown

c21

fc-fabric

connected

configured

 

unknown

c21::50020f2300006355

disk

connected

configured

 

unusable

 

 

 

 

 

 

FRU tests available for the A4/B4 FC Link Segment

The switchtest can only be run from the Storage Service Processor

The linktest will be able to isolate the switch and the GBIC on the switch. It will not be able to isolate the cable or the Sun StorEdge T3+ array controller.

To Isolate the A4/B4 FC Link

1.Quiesce the I/O on the A4/B4 FC link path.

2.Run linktest from the Storage Automated Diagnostic Environment GUI to isolate suspected failing components.

Alternatively, follow these steps:

1.Quiesce the I/O on the A4/B4 FC link path.

2.Run switchtest to test the entire link (re-create the problem).

3.Break the connnection by uncabling the link.

4.Insert the loopback connector into the switch port.

44 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 60
Image 60
Sun Microsystems 6900 Series, 3900 Series FRU tests available for the A4/B4 FC Link Segment, To Isolate the A4/B4 FC Link