Sun Microsystems 6900 Series, 3900 Series 7A3/B3 FC Link Storage Service Processor-Side Event

Models: 6900 Series 3900 Series

1 162
Download 162 pages 27.82 Kb
Page 52
Image 52

Site

:

FSDE LAB Broomfield CO

Source

:

diag.xxxxx.xxx.com

Severity :

Normal

 

Category :

Switch

Key: switch:100000c0dd0057bd

EventType:

StateChangeEvent.M.port.1

EventTime:

01/08/2002 18:28:38

’port.1’ in SWITCH diag-sw1a (ip=192.168.0.30) is now Not-Available (status-state changed from ’Online’ to ’Offline’):

Info:

A port on the switch has logged out of the fabric and gone offline Action:

1.Verify cables, GBICs and connections along Fibre Channel path

2.Check Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path

3.Verify correct FC switch configuration

FIGURE 3-7A3/B3 FC Link Storage Service Processor-Side Event

Site

:

FSDE LAB Broomfield CO

Source

:

diag.xxxxx.xxx.com

Severity :

Normal

 

Category :

Switch

Key: switch:100000c0dd00cbfe

EventType:

StateChangeEvent.M.port.1

EventTime:

01/08/2002 18:28:40

’port.1’ in SWITCH diag-sw2a (ip=192.168.0.32) is now Not-Available (status-state changed from ’Online’ to ’Offline’):

Info:

A port on the switch has logged out of the fabric and gone offline Action:

1.Verify cables, GBICs and connections along Fibre Channel path

2.Check Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path

3.Verify correct FC switch configuration

FIGURE 3-8A3/B3 FC Link Storage Service Processor-Side Event

36 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 52
Image 52
Sun Microsystems 6900 Series, 3900 Series manual 7A3/B3 FC Link Storage Service Processor-Side Event