Site | : | FSDE LAB Broomfield CO | |
Source | : | diag.xxxxx.xxx.com | |
Severity : | Normal |
| |
Category : | Switch | Key: switch:100000c0dd0057bd | |
EventType: | StateChangeEvent.M.port.1 | ||
EventTime: | 01/08/2002 18:28:38 |
’port.1’ in SWITCH
Info:
A port on the switch has logged out of the fabric and gone offline Action:
1.Verify cables, GBICs and connections along Fibre Channel path
2.Check Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path
3.Verify correct FC switch configuration
FIGURE 3-7 A3/B3 FC Link Storage Service Processor-Side Event
Site | : | FSDE LAB Broomfield CO | |
Source | : | diag.xxxxx.xxx.com | |
Severity : | Normal |
| |
Category : | Switch | Key: switch:100000c0dd00cbfe | |
EventType: | StateChangeEvent.M.port.1 | ||
EventTime: | 01/08/2002 18:28:40 |
’port.1’ in SWITCH
Info:
A port on the switch has logged out of the fabric and gone offline Action:
1.Verify cables, GBICs and connections along Fibre Channel path
2.Check Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path
3.Verify correct FC switch configuration
FIGURE 3-8 A3/B3 FC Link Storage Service Processor-Side Event
36 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002