To Verify the Data Host

An error in the A1/B1 FC link can cause a path to go offline in the multipathing software.

CODE EXAMPLE 3-1 luxadm(1M) Display

#luxadm display

/dev/rdsk/c6t29000060220041F96257354230303052d0s2 DEVICE PROPERTIES for disk: /dev/rdsk/ c6t29000060220041F96257354230303052d0s2

Status(Port

A):

O.K.

Status(Port

B):

O.K.

Vendor:

 

SUN

Product ID:

 

SESS01

WWN(Node):

 

2a000060220041f4

WWN(Port A):

2b000060220041f4

WWN(Port B):

2b000060220041f9

Revision:

 

080C

Serial Num:

 

Unsupported

Unformatted

capacity:

102400.000 MBytes

Write Cache:

Enabled

Read Cache:

 

Enabled

Minimum prefetch:

0x0

Maximum prefetch:

0x0

Device Type:

Disk device

Path(s):

 

 

/dev/rdsk/c6t29000060220041F96257354230303052d0s2 /devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw

Controller

/devices/pci@6,4000/SUNW,qlc@3/fp@0,0

Device Address

2b000060220041f9,0

Class

primary

State

OFFLINE

Controller

/devices/pci@6,4000/SUNW,qlc@2/fp@0,0

Device Address

2b000060220041f4,0

Class

primary

State

ONLINE

...

 

Chapter 3 Troubleshooting the Fibre Channel Links 25

For Internal Use Only

Page 41
Image 41
Sun Microsystems 3900 Series, 6900 Series manual To Verify the Data Host, Offline