C H A P T E R 3
Troubleshooting the Fibre Channel Links
A1/B1 Fibre Channel (FC) Link
If a problem occurs with the A1/B1 FC link:
■In a Sun StorEdge 3900 series system, the Sun StorEdge T3+ array will fail over.
■In a Sun StorEdge 6900 series system, no Sun StorEdge T3+ array will fail over, but a severe problem can cause a path to go offline.
FIGURE 3-1, FIGURE 3-2, and FIGURE 3-3 are examples of A1/B1 Fibre Channel Link Notification Events.
Site | : | FSDE LAB Broomfield CO | |
Source | : | diag.xxxxx.xxx.com | |
Severity : | Normal |
| |
Category : | Message | Key: message:diag.xxxxx.xxx.com | |
EventType: | LogEvent.driver.LOOP_OFFLINE | ||
EventTime: | 01/08/2002 14:34:45 |
Found 1 ’driver.LOOP_OFFLINE’ error(s) in logfile: /var/adm/messages on
diag.xxxxx.xxx.com (id=80fee746):
info: Loop Offline
Jan 8 14:34:25 WWN: Received 2 ’Loop Offline’ message(s) [threshold is 1
in 5mins]
Qlogic qlc(0): Loop OFFLINE ’
FIGURE 3-1 Data Host Notification of Intermittent Problems
23