C H A P T E R 3

Troubleshooting the Fibre Channel Links

A1/B1 Fibre Channel (FC) Link

If a problem occurs with the A1/B1 FC link:

In a Sun StorEdge 3900 series system, the Sun StorEdge T3+ array will fail over.

In a Sun StorEdge 6900 series system, no Sun StorEdge T3+ array will fail over, but a severe problem can cause a path to go offline.

FIGURE 3-1, FIGURE 3-2, and FIGURE 3-3are examples of A1/B1 Fibre Channel Link Notification Events.

Site

:

FSDE LAB Broomfield CO

Source

:

diag.xxxxx.xxx.com

Severity :

Normal

 

Category :

Message

Key: message:diag.xxxxx.xxx.com

EventType:

LogEvent.driver.LOOP_OFFLINE

EventTime:

01/08/2002 14:34:45

Found 1 ’driver.LOOP_OFFLINE’ error(s) in logfile: /var/adm/messages on

diag.xxxxx.xxx.com (id=80fee746):

info: Loop Offline

Jan 8 14:34:25 WWN: Received 2 ’Loop Offline’ message(s) [threshold is 1

in 5mins] Last-Message: ’diag.xxxxx.xxx.com qlc: [ID 686697 kern.info] NOTICE:

Qlogic qlc(0): Loop OFFLINE ’

FIGURE 3-1Data Host Notification of Intermittent Problems

23

Page 39
Image 39
Sun Microsystems 3900 Series, 6900 Series A1/B1 Fibre Channel FC Link, 1Data Host Notification of Intermittent Problems