For detailed information about the SUNWsecfg scripts, refer to the Sun StorEdge 3900 and 6900 Series Reference Manual.
▼To Replace a Failed Virtualization Engine
1.Replace the old (failed) virtualization engine unit with a new unit.
2.Identify the MAC address of the new unit and replace the old MAC address with the new one in the /etc/ethers file:
8:0:20:7d:82:9e virtualization
3.Verify that RARP is running on the Storage Service Processor.
4.Disable the switch port:
#/opt/SUNWsecfg/flib/setveport
5.Power on the new unit.
6.Log in to the new unit, for example:
#telnet v1a virtualization
7.From the User Service Utility Menu, enter 9 to clear the SAN database.
8.Choose Quit to clear the SAN database.
9.Configure the new unit:
#setupve
10.Check the configuration:
#checkve
84Sun StorEdge 3900 and 6900 Series Troubleshooting Guide — March 2002