Site | : FSDE LAB Broomfield CO | |
Source | : diag.xxxxx.xxx.com | |
Severity : Normal |
| |
Category : Switch | Key: switch:100000c0dd0061bb |
EventType: StateChangeEvent.X.port.1
EventTime: 01/08/2002 17:38:32
’port.1’ | in SWITCH | |
state changed from | ’Online’ to ’Admin’): | |
Site | : FSDE LAB Broomfield CO | |
Source | : diag.xxxxx.xxx.com | |
Severity | : Normal |
|
Category | : San | Key: switch:100000c0dd0061bb:1 |
EventType: LinkEvent.ITW.switchve
EventTime: 01/08/2002 17:39:47
Destination: port 1 on ve
An invalid transmission word (ITW) was detected between two components. This could indicate a potential problem.
Cause:
Likely Causes are: GBIC, FC Cable and device optical connections. Action:
To isolate further please run the Storage Automated Diagnostic Environment tests associated with this link segment.
FIGURE 3-5 A2/B2 FC Link Storage Service Processor Side Event
30 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002