Troubleshooting the T1/T2 Data Path

Notes

There are two T Port links for redundancy.

If one of the two links is lost, no Sun StorEdge T3+ array LUN failover will occur, and no pathing failures will be noted.

If both T Port links fail, there will be a Sun StorEdge T3+ array LUN failover, as one of the virtualization engines take control of the I/O operations. One of the Sun StorEdge T3+ array LUNs will failover, as all I/O is routed to the controlling virtualization engine.

The host will notice a pathing failure in its multipathing software.

102 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 118
Image 118
Sun Microsystems 6900 Series, 3900 Series manual Troubleshooting the T1/T2 Data Path