A P P E N D I X A
Virtualization Engine References
This Appendix contains the following Tables:
■Table
■Table A-2 “SRN/SNMP Single Point of Failure Table”
■Table
■Table
TABLE
TABLE A-1 SRN and SNMP Reference
SRN | Description | Corrective Action |
|
|
|
1xxxx | Disk drive Check Condition status. xxxx is | If too many Check Conditions are returned, |
| the Unit Error Code. | then check the link status. |
| The Unit Error Codes are returned by the |
|
| drive in Sense Data bytes |
|
| to the SCSI Request Sense command. |
|
|
|
|
70000 | SAN Configuration has changed. |
|
|
|
|
70001 | Rebuild process has started. |
|
|
|
|
70002 | Rebuild is completed without error. |
|
|
|
|
70003 | Rebuild is aborted with a read error. This | If a spare drive is available, it will be |
| means that the drive copying information | brought in and used to replace the failed |
| cannot read from the primary drive. | drive. If no spare is available, replace the |
|
| failed drive with a new drive. |
|
|
|
70004 | Write error is reported by follower. If the | If a spare drive is available, it will be |
| initiator is master, then its follower has | brought in and used to replace the failed |
| detected a write error on a member within | drive. If no spare is available, replace the |
| a mirror drive. | failed drive with a new drive. |
|
|
|
125