A P P E N D I X A

Virtualization Engine References

This Appendix contains the following Tables:

Table A-1“SRN and SNMP Reference”

Table A-2SRN/SNMP Single Point of Failure Table

Table A-3 “Port Communication”

Table A-4 “Service Codes”

TABLE A-1provides an explanation of Service Request Numbers for the virtualization engine.

TABLE A-1SRN and SNMP Reference

SRN

Description

Corrective Action

 

 

 

1xxxx

Disk drive Check Condition status. xxxx is

If too many Check Conditions are returned,

 

the Unit Error Code.

then check the link status.

 

The Unit Error Codes are returned by the

 

 

drive in Sense Data bytes 20-21 in response

 

 

to the SCSI Request Sense command.

 

 

 

 

70000

SAN Configuration has changed.

 

 

 

 

70001

Rebuild process has started.

 

 

 

 

70002

Rebuild is completed without error.

 

 

 

 

70003

Rebuild is aborted with a read error. This

If a spare drive is available, it will be

 

means that the drive copying information

brought in and used to replace the failed

 

cannot read from the primary drive.

drive. If no spare is available, replace the

 

 

failed drive with a new drive.

 

 

 

70004

Write error is reported by follower. If the

If a spare drive is available, it will be

 

initiator is master, then its follower has

brought in and used to replace the failed

 

detected a write error on a member within

drive. If no spare is available, replace the

 

a mirror drive.

failed drive with a new drive.

 

 

 

125

For Internal Use Only

Page 141
Image 141
Sun Microsystems 3900 Series manual Table A-2 SRN/SNMP Single Point of Failure Table, Table A-1SRN and Snmp Reference