69
CHAPTER 7
Troubleshooting VirtualizationEngine Devices
This chapter describes how to troubleshoot the virtualization engine component of a
Sun StorEdge 6900 series system.
This chapter contains the following sections:
“Virtualization Engine Description” on page 69
“TranslatingHost Device Names” on page 78
“Sun StorEdge 6900 Series Multipathing Example” on page 89
“Virtualization Engine Event Grid” on page95

Virtualization Engine Description

The virtualization engine supports the multipathing functionality of the Sun
StorEdge T3+ array.Each virtualization engine has physical access to all underlying
Sun StorEdge T3+ arrays and controls access to half of the Sun StorEdge T3+ arrays.
The virtualization engine has the ability to assume control of all arrays in the event
of component failure.The configuration is maintained between virtualization engine
pairs through redundant T Port connections by way of a pair of Sun StorEdge
network FC switch-8 or switch-16 switches.