TABLE A-1 SRN and SNMP Reference
SRN | Description | Corrective Action |
|
|
|
70005 | Write error is detected by master. | If a spare drive is available, it will be |
| If the initiator is master, then it has detected | brought in and used to replace the failed |
| a write error on a member within a mirror | drive. If no spare is available, replace the |
| drive. | failed drive with a new drive. |
|
|
|
70006 | virtualization | Internal error. Update firmware. |
| engine communication has failed. |
|
|
|
|
70007 | Rebuild is aborted with write error. This | If a spare drive is available, it will be |
| means the primary drive cannot write to | brought in and used to replace the failed |
| the drive being built. | drive. If no spare is available, replace the |
|
| failed drive with a new drive. |
|
|
|
70008 | Read error is reported by follower. If the | If a spare drive is available, it will be |
| initiator is master, then its follower has | brought in and used to replace the failed |
| detected a read error on a member within a | drive. If no spare is available, replace the |
| mirror drive. | failed drive with a new drive. |
|
|
|
70009 | Read error is detected by master. If the | If a spare drive is available, it will be |
| initiator is master, then it has detected a | brought in and used to replace the failed |
| read error on a member within a mirror | drive. If no spare is available, replace the |
| drive. | failed drive with a new drive. |
|
|
|
70010 | CleanUp configuration table is completed. |
|
|
|
|
70020 | SAN physical configuration has changed. | If unintentional, check condition of drives. |
|
|
|
70021 | Drive is offline. | If unintentional, check condition of drives. |
|
|
|
70022 | virtualization engine is offline. | If unintentional, check condition of drives. |
|
|
|
70023 | Drive is unresponsive. | Check condition of drives. |
|
|
|
70024 | For Sun StorEdge T3+ array pack: Master |
|
| virtualization engine has detected the |
|
| partner virtualization engine’s IP Address. |
|
|
|
|
70025 | For Sun StorEdge T3+ array pack: Master | Check the Ethernet connection between the |
| virtualization engine is unable to detect the | two virtualization engines. |
| partner virtualization engine’s IP Address. |
|
|
|
|
70030 | SAN configuration changed by SV SAN |
|
| Builder. |
|
|
|
|
70040 | Host zoning configuration has changed. |
|
|
|
|
70050 | MultiPath drive Failover. | Check MultiPath drive. |
|
|
|
70051 | MultiPath drive Failback. |
|
|
|
|
70098 | Instant Copy degrade. | If no spare is available, replace the failed |
|
| drive with a new drive. |
|
|
|
70099 | Degrade because the drive has disappeared. | Reinsert the missing drive, or replace it |
|
| with a drive of equal or greater capacity. |
|
|
|
126 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002