Sun Microsystems 6900 Series, 3900 Series manual Write error is detected by master

Models: 6900 Series 3900 Series

1 162
Download 162 pages 27.82 Kb
Page 142
Image 142

TABLE A-1SRN and SNMP Reference

SRN

Description

Corrective Action

 

 

 

70005

Write error is detected by master.

If a spare drive is available, it will be

 

If the initiator is master, then it has detected

brought in and used to replace the failed

 

a write error on a member within a mirror

drive. If no spare is available, replace the

 

drive.

failed drive with a new drive.

 

 

 

70006

virtualization engine-to-virtualization

Internal error. Update firmware.

 

engine communication has failed.

 

 

 

 

70007

Rebuild is aborted with write error. This

If a spare drive is available, it will be

 

means the primary drive cannot write to

brought in and used to replace the failed

 

the drive being built.

drive. If no spare is available, replace the

 

 

failed drive with a new drive.

 

 

 

70008

Read error is reported by follower. If the

If a spare drive is available, it will be

 

initiator is master, then its follower has

brought in and used to replace the failed

 

detected a read error on a member within a

drive. If no spare is available, replace the

 

mirror drive.

failed drive with a new drive.

 

 

 

70009

Read error is detected by master. If the

If a spare drive is available, it will be

 

initiator is master, then it has detected a

brought in and used to replace the failed

 

read error on a member within a mirror

drive. If no spare is available, replace the

 

drive.

failed drive with a new drive.

 

 

 

70010

CleanUp configuration table is completed.

 

 

 

 

70020

SAN physical configuration has changed.

If unintentional, check condition of drives.

 

 

 

70021

Drive is offline.

If unintentional, check condition of drives.

 

 

 

70022

virtualization engine is offline.

If unintentional, check condition of drives.

 

 

 

70023

Drive is unresponsive.

Check condition of drives.

 

 

 

70024

For Sun StorEdge T3+ array pack: Master

 

 

virtualization engine has detected the

 

 

partner virtualization engine’s IP Address.

 

 

 

 

70025

For Sun StorEdge T3+ array pack: Master

Check the Ethernet connection between the

 

virtualization engine is unable to detect the

two virtualization engines.

 

partner virtualization engine’s IP Address.

 

 

 

 

70030

SAN configuration changed by SV SAN

 

 

Builder.

 

 

 

 

70040

Host zoning configuration has changed.

 

 

 

 

70050

MultiPath drive Failover.

Check MultiPath drive.

 

 

 

70051

MultiPath drive Failback.

 

 

 

 

70098

Instant Copy degrade.

If no spare is available, replace the failed

 

 

drive with a new drive.

 

 

 

70099

Degrade because the drive has disappeared.

Reinsert the missing drive, or replace it

 

 

with a drive of equal or greater capacity.

 

 

 

126 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 142
Image 142
Sun Microsystems 6900 Series, 3900 Series manual Write error is detected by master