The following table lists all of the events for the Sun StorEdge T3+ array.

Category

Component

EventType

Sev

Action

Description

Information

 

 

 

 

 

 

 

 

t3

power.temp

Alarm+

 

 

The state of

 

 

 

 

 

 

 

power.u1pcu1.PowTe

 

 

 

 

 

 

 

mp on diag213

 

 

 

 

 

 

 

(ip=xxx.20.67.213) is

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

 

t3

disk.port

Alarm-

Red

Y

[ Info/Action ] The

Information: The Sun

 

 

 

 

 

state of disk.u1d1.

StorEdge T3+ array

 

 

 

 

 

Port1State on Sun

has reported that one

 

 

 

 

 

StorEdge T3+ array

port of a dual-ported

 

 

 

 

 

t300 changed from OK

disk has failed.

 

 

 

 

 

to failed.

 

 

 

 

 

 

 

 

Recommended action:

 

 

 

 

 

 

1.

Telnet to affected

 

 

 

 

 

 

 

Sun StorEdge T3+

 

 

 

 

 

 

 

array

 

 

 

 

 

 

2. Verify disk state in

 

 

 

 

 

 

 

fru stat, fru list,

 

 

 

 

 

 

 

and vol stat.’

 

 

 

 

 

 

 

t3

interface.

Alarm-

Red

Y

[ Info/Action ] The

Information: The Sun

 

loopcard.cab

 

 

 

state of

StorEdge T3+ array

 

le

 

 

 

loopcable.u1l1.CableSt

has reported that a

 

 

 

 

 

ate changed from OK

loopcard is in a failed

 

 

 

 

 

to failed.

state.

 

 

 

 

 

Drive Status

Recommended action:

 

 

 

 

 

Messages:

1.

Telnet to affected

 

 

 

 

 

Value Description

 

Sun StorEdge T3+

 

 

 

 

 

0 Drive mounted

 

array.

 

 

 

 

 

2 Drive present

2.

Verify tje loopcard

 

 

 

 

 

3 Drive is spun up

 

state with fru stat.

 

 

 

 

 

4 Drive is disable

3.

Verify the

 

 

 

 

 

5 Drive has been

 

matching firmware

 

 

 

 

 

replaced

 

with the other

 

 

 

 

 

7 Invalid system area

 

loopcard.

 

 

 

 

 

on drive

4.

Re-enable the

 

 

 

 

 

9 Drive not present

 

loopcard if

 

 

 

 

 

D Drive disabled;

 

possible (enable

 

 

 

 

 

drive is being

 

u (encid)[12]

 

 

 

 

 

reconstructed

 

). Replace loopcard

 

 

 

 

 

S Drive substituted

 

if necessary.

 

 

 

 

 

 

5. Re-enable the disk

 

 

 

 

 

 

 

if possible

 

 

 

 

 

 

6. Replace the disk, if

 

 

 

 

 

 

 

necessary.

 

 

 

 

 

 

 

 

110 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 126
Image 126