The following table lists all of the events for the Sun StorEdge T3+ array.
Category | Component | EventType | Sev | Action | Description | Information | |
|
|
|
|
|
|
|
|
t3 | power.temp | Alarm+ |
|
| The state of |
|
|
|
|
|
|
| power.u1pcu1.PowTe |
|
|
|
|
|
|
| mp on diag213 |
|
|
|
|
|
|
| (ip=xxx.20.67.213) is |
|
|
|
|
|
|
| Normal |
|
|
|
|
|
|
|
|
| |
t3 | disk.port | Alarm- | Red | Y | [ Info/Action ] The | Information: The Sun | |
|
|
|
|
| state of disk.u1d1. | StorEdge T3+ array | |
|
|
|
|
| Port1State on Sun | has reported that one | |
|
|
|
|
| StorEdge T3+ array | port of a | |
|
|
|
|
| t300 changed from OK | disk has failed. | |
|
|
|
|
| to failed. |
|
|
|
|
|
|
|
| Recommended action: | |
|
|
|
|
|
| 1. | Telnet to affected |
|
|
|
|
|
|
| Sun StorEdge T3+ |
|
|
|
|
|
|
| array |
|
|
|
|
|
| 2. Verify disk state in | |
|
|
|
|
|
|
| fru stat, fru list, |
|
|
|
|
|
|
| and vol stat.’ |
|
|
|
|
|
|
| |
t3 | interface. | Alarm- | Red | Y | [ Info/Action ] The | Information: The Sun | |
| loopcard.cab |
|
|
| state of | StorEdge T3+ array | |
| le |
|
|
| loopcable.u1l1.CableSt | has reported that a | |
|
|
|
|
| ate changed from OK | loopcard is in a failed | |
|
|
|
|
| to failed. | state. | |
|
|
|
|
| Drive Status | Recommended action: | |
|
|
|
|
| Messages: | 1. | Telnet to affected |
|
|
|
|
| Value Description |
| Sun StorEdge T3+ |
|
|
|
|
| 0 Drive mounted |
| array. |
|
|
|
|
| 2 Drive present | 2. | Verify tje loopcard |
|
|
|
|
| 3 Drive is spun up |
| state with fru stat. |
|
|
|
|
| 4 Drive is disable | 3. | Verify the |
|
|
|
|
| 5 Drive has been |
| matching firmware |
|
|
|
|
| replaced |
| with the other |
|
|
|
|
| 7 Invalid system area |
| loopcard. |
|
|
|
|
| on drive | 4. | |
|
|
|
|
| 9 Drive not present |
| loopcard if |
|
|
|
|
| D Drive disabled; |
| possible (enable |
|
|
|
|
| drive is being |
| u (encid)[12] |
|
|
|
|
| reconstructed |
| ). Replace loopcard |
|
|
|
|
| S Drive substituted |
| if necessary. |
|
|
|
|
|
| 5. | |
|
|
|
|
|
|
| if possible |
|
|
|
|
|
| 6. Replace the disk, if | |
|
|
|
|
|
|
| necessary. |
|
|
|
|
|
|
|
|
110 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002