Note
▼To Verify the A2/B2 FC Link
You can check the A2/B2 FC link using the Storage Automated Diagnostic Environment,
Refer to Chapter 5 of the Storage Automated Diagnostic Environment User’s Guide for more information.
FRU Tests Available for A2/B2 FC Link Segment
■The linktest is not available.
■The switch and/or
■Can be used only in conjunction with the loopback connector.
■Cannot be cabled to the virtualization engine while switchtest runs.
■No virtualization engine tests are available at this time.
▼To Isolate the A2/B2 FC Link
1.Quiesce the I/O on the A2/B2 FC link path.
2.Break the connection by uncabling the link.
3.Insert the loopback connector into the switch port.
4.Run switchtest:
a. If the test fails, replace the GBIC and rerun switchtest. b. If the test fails again, replace the switch.
Chapter 3 Troubleshooting the Fibre Channel Links 33