Chapter 3 Troubleshooting the Fibre Channel Links 33
For Internal Use Only
Note – Youcan find procedures for restoring virtualization engine settings in the
Sun StorEdge 3900 and 6900 Series Reference Manual.
▼To Verify the A2/B2 FC LinkYoucan check the A2/B2 FC link using the Storage Automated Diagnostic
Environment, Diagnose—Testfrom Topology functionality. The Storage Automated
Diagnostic Environment’s implementation of diagnostic tests verifies the operation
of user-selected components. Using the Topologyview, you can select specific tests,
subtests, and test options.
Refer to Chapter 5 of the Storage Automated Diagnostic Environment User’s Guide for
more information.
FRU TestsAvailable for A2/B2 FC Link Segment■The linktest is not available.
■The switch and/or GBIC—switchtest test:
■Can be used only in conjunction with the loopback connector.
■Cannot be cabled to the virtualization engine while switchtest runs.
■No virtualization engine tests are available at this time.
▼To Isolate the A2/B2 FC Link1. Quiesce the I/O on the A2/B2 FC link path.
2. Break the connection by uncabling the link.
3. Insert the loopback connector into the switch port.
4. Run switchtest:
a. If the test fails, replace the GBIC and rerun switchtest.
b. If the test fails again, replace the switch.