A3/B3 Fibre Channel (FC) Link
If a problem occurs with the A3/B3 FC link:
■In a Sun StorEdge 3900 series system, the Sun StorEdge T3+ array will fail over.
■In a Sun StorEdge 6900 series system, no Sun StorEdge T3+ array will fail over, but a severe problem can cause a path to go offline.
FIGURE 3-6, FIGURE 3-7, and FIGURE 3-8 are examples of A3/B3 FC link Notification Events.
Site | : | FSDE LAB Broomfield CO | |
Source | : | diag.xxxxx.xxx.com | |
Severity : | Normal |
| |
Category : | Message | Key: message:diag.xxxxx.xxx.com | |
EventType: | LogEvent.driver.MPXIO_offline | ||
EventTime: | 01/08/2002 18:25:18 |
Found 2 ’driver.MPXIO_offline’ warning(s) in logfile: /var/adm/messages on diag.xxxxx.xxx.com (id=80fee746):
Jan 8 18:24:24 WWN:2b000060220041f9 diag.xxxxx.xxx.com mpxio: [ID 779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303053 (ssd19) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0
(fp1) | to target | address: 2b000060220041f9,1 is offline | |
Jan 8 | 18:24:24 | WWN:2b000060220041f9 | diag.xxxxx.xxx.com mpxio: [ID |
779286 kern.info] /scsi_vhci/ssd@g29000060220041f96257354230303052 (ssd18) multipath status: degraded, path /pci@6,4000/SUNW,qlc@3/fp@0,0 (fp1) to target address: 2b000060220041f9,0 is offline
Site | : | FSDE LAB Broomfield CO | |
Source | : | diag.xxxxx.xxx.com | |
Severity : | Normal |
| |
Category : | Message | Key: message:diag.xxxxx.xxx.com | |
EventType: | LogEvent.driver.Fabric_Warning | ||
EventTime: | 01/08/2002 18:25:18 |
Found 1 ’driver.Fabric_Warning’ warning(s) in logfile: /var/adm/messages on diag.xxxxx.xxx.com (id=80fee746):
Info:
Fabric warning
Jan 8 18:24:04 WWN:2b000060220041f9 | diag.xxxxx.xxx.com fp: [ID 517869 | |
kern.warning] WARNING: fp(1): N_x | Port with D_ID=104000, | |
PWWN=2b000060220041f9 disappeared | from fabric | |
|
| |
FIGURE |
| |
Chapter 3 | Troubleshooting the Fibre Channel Links 35 |