To verify the failover luxadm display can be used, the failed path will be marked OFFLINE, as shown in CODE EXAMPLE
CODE EXAMPLE
# luxadm display /dev/rdsk/c26t60020F200000644>
DEVICE PROPERTIES for disk: /dev/rdsk/ c26t60020F20000064433C3352A60003E82Fd0s2
Status(Port | A): | O.K. |
Status(Port | B): | O.K. |
Vendor: |
| SUN |
Product ID: |
| T300 |
WWN(Node): |
| 50020f2000006443 |
WWN(Port A): | 50020f2300006355 | |
WWN(Port B): | 50020f2300006443 | |
Revision: |
| 0118 |
Serial Num: |
| Unsupported |
Unformatted | capacity: | 488642.000 MBytes |
Write Cache: | Enabled | |
Read Cache: |
| Enabled |
Minimum prefetch: | 0x0 | |
Maximum prefetch: | 0x0 | |
Device Type: | Disk device | |
Path(s): |
|
|
/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2 /devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw
Controller | /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0 |
Device Address | 50020f2300006355,1 |
Class | primary |
State | OFFLINE |
Controller | /devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0 |
Device Address | 50020f2300006443,1 |
Class | secondary |
State | ONLINE |
Note
Chapter 3 Troubleshooting the Fibre Channel Links 43
For Internal Use Only