To verify the failover luxadm display can be used, the failed path will be marked OFFLINE, as shown in CODE EXAMPLE 3-7.

CODE EXAMPLE 3-7Failed Path marked OFFLINE

# luxadm display /dev/rdsk/c26t60020F200000644>

DEVICE PROPERTIES for disk: /dev/rdsk/ c26t60020F20000064433C3352A60003E82Fd0s2

Status(Port

A):

O.K.

Status(Port

B):

O.K.

Vendor:

 

SUN

Product ID:

 

T300

WWN(Node):

 

50020f2000006443

WWN(Port A):

50020f2300006355

WWN(Port B):

50020f2300006443

Revision:

 

0118

Serial Num:

 

Unsupported

Unformatted

capacity:

488642.000 MBytes

Write Cache:

Enabled

Read Cache:

 

Enabled

Minimum prefetch:

0x0

Maximum prefetch:

0x0

Device Type:

Disk device

Path(s):

 

 

/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2 /devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw

Controller

/devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address

50020f2300006355,1

Class

primary

State

OFFLINE

Controller

/devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address

50020f2300006443,1

Class

secondary

State

ONLINE

Note This type of error may also cause the device to show up "unusable" in cfgadm, as shown in CODE EXAMPLE 3-8.

Chapter 3 Troubleshooting the Fibre Channel Links 43

For Internal Use Only

Page 59
Image 59
Sun Microsystems 3900 Series, 6900 Series manual Offline