Chapter 3 Troubleshooting the Fibre Channel Links 43

For Internal Use Only

Toverify the failover luxadm display can be used, the failed path will be marked

OFFLINE, as shown in CODEEXAMPLE 3-7.
CODEEXAMPLE 3-7 Failed Path marked OFFLINE
Note – This type of error may also cause the device to show up "unusable" in

cfgadm, as shown in CODEEXAMPLE 3-8.

# luxadm display /dev/rdsk/c26t60020F200000644>
DEVICE PROPERTIES for disk: /dev/rdsk/
c26t60020F20000064433C3352A60003E82Fd0s2
Status(Port A): O.K.
Status(Port B): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f2000006443
WWN(Port A): 50020f2300006355
WWN(Port B): 50020f2300006443
Revision: 0118
Serial Num: Unsupported
Unformatted capacity: 488642.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2
/devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw
Controller /devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0
Device Address 50020f2300006355,1
Class primary
State OFFLINE
Controller /devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0
Device Address 50020f2300006443,1
Class secondary
State ONLINE