TABLE A-1SRN and SNMP Reference

SRN

Description

Corrective Action

 

 

 

72005

Failed to check for SAN changes.

 

 

 

 

72006

Failed to read SAN event log.

 

 

 

 

72007

SLIC daemon connection is down.

Wait for 1-5 minutes for backup daemon to

 

 

come up. If it doesn’t, check the network

 

 

connection for virtualization engine halt, or

 

 

hardware failure.

 

 

 

TABLE A-2SRN/SNMP Single Point of Failure Table

 

 

 

SRN after

 

 

 

Corrective

SRN

SNMP Description

Corrective Action

Action

 

 

 

 

70020

• SAN topology has changed

Check SAN cabling and connections

70020

70030

• Global SAN configuration has

between Sun StorEdge T3+ array

70030

70050*

changed.

and virtualization engine.

70051**

70021

• SAN configuration has changed.

Perform Sun StorEdge T3+ array

 

 

• A physical device is missing.

failback, if necessary.

 

 

 

 

 

70025

Partner’s virtualization engine’s IP is not

Check Ethernet cabling and

None.

 

reachable.

connections.

 

 

 

 

 

70020

• SAN topology has changed

• Check cabling and connections

70020

70030

• Global SAN configuration has

between virtualization engine.

70030

70050

changed.

• Cycle power on failed

70050

70025

• SAN configuration has changed.

virtualization engine, if fault LED

70024

70021

• Partner virtualization engine’s IP is

flashes.

70021

70022

not reachable.

• Perform Sun StorEdge T3+

70022

 

• A physical device is missing.

array failback, if necessary.

 

 

• A SLIC virtualization engine is

• Enable VERITAS path.

 

Readings

missing.

 

 

 

 

 

72007

When error halt on virtualization

 

 

 

 

 

 

engine (not master)

 

 

 

• SLIC daemon connection is inactive.

 

 

72000

Failed to check for SAN changes,

 

 

daemon error, check the SLIC

 

 

 

 

 

 

virtualization engine.

 

 

 

• Secondary daemon connection is

 

 

 

active.

 

 

 

 

 

 

* Sun StorEdge T3+ array LUN Failover.

 

 

** Sun StorEdge T3+ array LUN Failback.

 

 

 

 

 

 

128 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 144
Image 144
Sun Microsystems 6900 Series, 3900 Series manual Table A-2SRN/SNMP Single Point of Failure Table, 70051