TABLE A-4Service Codes

54

Unauthorized cabling configuration.

• Check cabling.

 

 

 

57

Too many HBAs attempting to log in.

• Check cabling.

 

 

 

60

Node mapping table cleared using SW2.

• No action required.

 

 

 

62

Improper SW2 setting.

• Correct SW2 setting.

 

 

• Cycle virtualization engine power.

 

 

 

126

Too many virtualization engines in SAN.

• Remove the extra virtualization engine.

 

 

• Cycle virtualization engine power.

 

 

 

130

Heartbeat connection between

• Correct problem.

 

virtualization engines is down.

• Cycle the power on the follower

 

 

virtualization engine.

 

 

 

 

400 - 599 Device side interface driver errors:

 

 

 

409

FC device-side type code invalid.

• Cycle power

 

 

• If problem persists, replace virtualization

 

 

engine.

 

 

 

434

Too many elastic store errors to continue.

• Check for faulty component and replace.

 

Elastic store errors result from a clock

• Cycle the power on the follower

 

mismatch between transmitter and receiver

virtualization engine.

 

and indicates an unreliable link. This error

 

 

can also occur if a device in the SAN loses

 

 

power unexpectedly.

 

 

 

 

130 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002