TABLE A-4 Service Codes
54 | Unauthorized cabling configuration. | • Check cabling. |
|
|
|
57 | Too many HBAs attempting to log in. | • Check cabling. |
|
|
|
60 | Node mapping table cleared using SW2. | • No action required. |
|
|
|
62 | Improper SW2 setting. | • Correct SW2 setting. |
|
| • Cycle virtualization engine power. |
|
|
|
126 | Too many virtualization engines in SAN. | • Remove the extra virtualization engine. |
|
| • Cycle virtualization engine power. |
|
|
|
130 | Heartbeat connection between | • Correct problem. |
| virtualization engines is down. | • Cycle the power on the follower |
|
| virtualization engine. |
|
|
|
| 400 - 599 Device side interface driver errors: | |
|
|
|
409 | FC | • Cycle power |
|
| • If problem persists, replace virtualization |
|
| engine. |
|
|
|
434 | Too many elastic store errors to continue. | • Check for faulty component and replace. |
| Elastic store errors result from a clock | • Cycle the power on the follower |
| mismatch between transmitter and receiver | virtualization engine. |
| and indicates an unreliable link. This error |
|
| can also occur if a device in the SAN loses |
|
| power unexpectedly. |
|
|
|
|
130 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002