CODE EXAMPLE 3-4 cfgadm -al

#cfgadm -al

Ap_Id

Type

Receptacle

Occupant

Condition

c0

scsi-bus

connected

configured

unknown

<snip>

 

 

 

 

#luxadm -e port

Found path to 2 HBA ports

/devices/pci@6,4000/SUNW,qlc@2/fp@0,0:devctlCONNECTED

/devices/pci@6,4000/SUNW,qlc@3/fp@0,0:devctlCONNECTED

#luxadm display /dev/rdsk/c6t29000060220041F96257354230303052d0s2

DEVICE PROPERTIES for disk: /dev/rdsk/ c6t29000060220041F96257354230303052d0s2

Status(Port

A):

O.K.

Status(Port

B):

O.K.

Vendor:

 

SUN

Product ID:

 

SESS01

WWN(Node):

 

2a000060220041f9

WWN(Port A):

2b000060220041f9

WWN(Port B):

2b000060220041f4

Revision:

 

080C

Serial Num:

 

Unsupported

Unformatted

capacity:

102400.000 MBytes

Write Cache:

Enabled

Read Cache:

 

Enabled

Minimum prefetch:

0x0

Maximum prefetch:

0x0

Device Type:

Disk device

Path(s):

 

 

/dev/rdsk/c6t29000060220041F96257354230303052d0s2 /devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw

Controller

/devices/pci@6,4000/SUNW,qlc@3/fp@0,0

Device Address

2b000060220041f9,0

Class

primary

State

ONLINE

Controller

/devices/pci@6,4000/SUNW,qlc@2/fp@0,0

Device Address

2b000060220041f4,0

Class

primary

State

OFFLINE

32 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002