Fibre Channel Links
The following sections provide troubleshooting information for the basic components and Fibre Channel links, listed in TABLE
TABLE
Link | Provides Fibre Channel Link Between these Components |
|
|
A1 to B1 | Datahost, sw1a, and sw1b |
A2 | sw1a and v1a* |
B2 | sw1b and v1b* |
A3 | v1a and sw2a* |
B3 | v1b and sw2b* |
A4 | Master Sun StorEdge T3+ array and the “A” path switch |
B4 | AltMaster Sun StorEdge T3+ array and the “B” path switch |
T1 to T2 | sw2a and sw2b* |
* Sun StorEdge 6900 series only
Note
By using the Storage Automated Diagnostic Environment, you should be able to isolate the problem to one particular segment of the configuration.
The information found in this section is based on the assumption that the Storage Automated Diagnostic Environment is running on the data host, and that it is configured to monitor host errors. If the Storage Automated Diagnostic Environment is not installed on the data host, there will be areas of limited monitoring, diagnosis and isolation.