Sun StorEdge T3+ Array Storage Service Processor Verification
1. Run port listmap on the Sun StorEdge T3+ array to see the failover event.
# t3b0:/:<1>port listmap |
|
|
|
| ||
port targetid addr_type | lun | volume | owner | access | ||
u1p1 | 0 | hard | 0 | vol1 | u1 | primary |
u1p1 | 0 | hard | 1 | vol2 | u1 | failover |
u2p1 | 1 | hard | 0 | vol1 | u1 | failover |
u2p1 | 1 | hard | 1 | vol2 | u1 | primary |
|
|
|
|
|
|
|
2.Compare the virtualization engine configuration to a saved configuration by running /opt/SUNWsecfg/runsecfg and choosing Verify Virtualization Engine Map.
The output is from the diff(1) command, which shows the lines that have been added, changed, or deleted. Notice that the active Sun StorEdge T3+ array controller WWN has changed for one of the Sun StorEdge T3+ arrays, indicating it is using its alternate path.
MANAGE CONFIGURATION FILES MENU
1)Display Virtualization Engine Map
2)Save Virtualization Engine Map
3)Verify Virtualization Engine Map
4)Help
5)Return
Select configuration option above:> 3
Verifying Virtualization Engine map for | v1 |
| |||||||
ERROR: virtualization engine map for v1 | has changed. |
| |||||||
18c18 |
|
|
|
|
|
|
|
| |
< | t3b01 | 5 | T49153 | 116.7 | 0.7 | 50020F230000725B | 1 | ||
> t3b01 | 5 | T49153 | 116.7 | 0.7 | 50020F2300006DFA | 1 | |||
28c28 |
|
|
|
|
|
|
|
| |
< t3b01 | T49153 | 50020F230000725B |
| 60020F2000006DFA |
| ||||
> t3b01 | T49153 | 50020F2300006DFA |
| 60020F2000006DFA |
| ||||
37c37 |
|
|
|
|
|
|
|
| |
< I00002 | 2900006022004186 | v1b |
| Yes | 08.14 | 0 | |||
> I00002 | 2900006022004186 | Unknown |
| No | Unknown | 0 | |||
46d45 |
|
|
|
|
|
|
|
| |
< Undefined |
| 210000E08B026C0F I00002 | Yes | 0 | |||||
| checkvemap: | virtualization engine map v1 verification complete: FAIL. |
FIGURE 8-3 Manage Configuration Files Menu
106 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002