Sun StorEdge T3+ Array Storage Service Processor Verification

1. Run port listmap on the Sun StorEdge T3+ array to see the failover event.

# t3b0:/:<1>port listmap

 

 

 

 

port targetid addr_type

lun

volume

owner

access

u1p1

0

hard

0

vol1

u1

primary

u1p1

0

hard

1

vol2

u1

failover

u2p1

1

hard

0

vol1

u1

failover

u2p1

1

hard

1

vol2

u1

primary

 

 

 

 

 

 

 

2.Compare the virtualization engine configuration to a saved configuration by running /opt/SUNWsecfg/runsecfg and choosing Verify Virtualization Engine Map.

The output is from the diff(1) command, which shows the lines that have been added, changed, or deleted. Notice that the active Sun StorEdge T3+ array controller WWN has changed for one of the Sun StorEdge T3+ arrays, indicating it is using its alternate path.

MANAGE CONFIGURATION FILES MENU

1)Display Virtualization Engine Map

2)Save Virtualization Engine Map

3)Verify Virtualization Engine Map

4)Help

5)Return

Select configuration option above:> 3

Verifying Virtualization Engine map for

v1

 

ERROR: virtualization engine map for v1

has changed.

 

18c18

 

 

 

 

 

 

 

 

<

t3b01

5

T49153

116.7

0.7

50020F230000725B

1

> t3b01

5

T49153

116.7

0.7

50020F2300006DFA

1

28c28

 

 

 

 

 

 

 

 

< t3b01

T49153

50020F230000725B

 

60020F2000006DFA

 

> t3b01

T49153

50020F2300006DFA

 

60020F2000006DFA

 

37c37

 

 

 

 

 

 

 

 

< I00002

2900006022004186

v1b

 

Yes

08.14

0

> I00002

2900006022004186

Unknown

 

No

Unknown

0

46d45

 

 

 

 

 

 

 

 

< Undefined

 

210000E08B026C0F I00002

Yes

0

 

checkvemap:

virtualization engine map v1 verification complete: FAIL.

FIGURE 8-3Manage Configuration Files Menu

106 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002

Page 122
Image 122
Sun Microsystems 6900 Series, 3900 Series manual 3Manage Configuration Files Menu