An error in the A1/B1 FC link can also cause a device to enter the “unusable” state in cfgadm. In this case, the output for luxadm
CODE EXAMPLE 3-2 cfgadm -al Display
... |
|
|
|
|
# cfgadm |
|
|
|
|
Ap_Id | Type | Receptacle | Occupant | Condition |
c0 | connected | configured | unknown | |
c0::dsk/c0t0d0 | disk | connected | configured | unknown |
c0::dsk/c0t1d0 | disk | connected | configured | unknown |
c1 | connected | configured | unknown | |
c1::dsk/c1t6d0 |
| connected | configured | unknown |
c2 | connected | configured | unknown | |
c2::210100e08b23fa25 | unknown | connected | unconfigured unknown | |
c2::2b000060220041f4 | disk | connected | configured | unknown |
c3 | connected | configured | unknown | |
c3::2b000060220041f9 | disk | connected | configured | unusable |
c4 | connected | unconfigured unknown | ||
c5 | fc | connected | unconfigured unknown | |
|
|
|
|
|
FRU Tests Available for A1/B1 FC Link Segment
■
■Available only if the Storage Automated Diagnostic Environment is installed on a data host
■Causes HBA to go “offline” and “online” during tests
■Switch
■Can be run while the link is still cabled and online (connected to HBA)
■You must specify a payload of 200 bytes or less when testing the A1/B1 FC link, while the link is connected to the HBA (limitation in HBA ASIC).
■Can be run only from the Storage Service Processor
■The dev option to switchtest is in the following format:
The FCAddress can be set to 0x0
26 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002