An error in the A1/B1 FC link can also cause a device to enter the “unusable” state in cfgadm. In this case, the output for luxadm -e port will show that a device that was “connected” changed to an “unconnected” state.

CODE EXAMPLE 3-2cfgadm -al Display

...

 

 

 

 

# cfgadm -al

 

 

 

 

Ap_Id

Type

Receptacle

Occupant

Condition

c0

scsi-bus

connected

configured

unknown

c0::dsk/c0t0d0

disk

connected

configured

unknown

c0::dsk/c0t1d0

disk

connected

configured

unknown

c1

scsi-bus

connected

configured

unknown

c1::dsk/c1t6d0

CD-ROM

connected

configured

unknown

c2

fc-fabric

connected

configured

unknown

c2::210100e08b23fa25

unknown

connected

unconfigured unknown

c2::2b000060220041f4

disk

connected

configured

unknown

c3

fc-fabric

connected

configured

unknown

c3::2b000060220041f9

disk

connected

configured

unusable

c4

fc-private

connected

unconfigured unknown

c5

fc

connected

unconfigured unknown

 

 

 

 

 

FRU Tests Available for A1/B1 FC Link Segment

HBA—qlctest(1M)

Available only if the Storage Automated Diagnostic Environment is installed on a data host

Causes HBA to go “offline” and “online” during tests

Switch switchtest(1M)

Can be run while the link is still cabled and online (connected to HBA)

You must specify a payload of 200 bytes or less when testing the A1/B1 FC link, while the link is connected to the HBA (limitation in HBA ASIC).

Can be run only from the Storage Service Processor

The dev option to switchtest is in the following format:

Port:IP-Address:FCAddress

The FCAddress can be set to 0x0

26 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002