5.If the switch or the GBIC show no errors, replace the remaining components in the following order:
a.Replace the virtualization
b.Replace the cable, recable the link, and monitor the link for errors.
c.Replace the virtualization engine, restore the virtualization engine settings, recable the link, and monitor the link for errors
6.Return the path to production.
The procedures for restoring virtualization engine settings are in the Sun StorEdge 3900 and 6900 Series Reference Manual.
34 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide • March 2002