Multipathing Options in the Sun StorEdge 6900 Series
Using the virtualization engines presents several challenges in how multipathing is handled in the Sun StorEdge 6900 series.
Unlike Sun StorEdge T3+ array and Sun StorEdge network FC
The following example illustrates a Sun StorEdge Traffic Manager problem on a Sun StorEdge 6900 series system.
#luxadm display
/dev/rdsk/c6t29000060220041F96257354230303052d0s2 DEVICE PROPERTIES for disk: /dev/rdsk/ c6t29000060220041F96257354230303052d0s2
Status(Port A): | O.K. |
Status(Port B): | O.K. |
Vendor: | SUN |
Product ID: | SESS01 |
WWN(Node): | 2a000060220041f4 |
WWN(Port A): | 2b000060220041f4 |
WWN(Port B): | 2b000060220041f9 |
Revision: | 080C |
Serial Num: | Unsupported |
Unformatted capacity: | 102400.000 MBytes |
Write Cache: | Enabled |
Read Cache: | Enabled |
Minimum prefetch: | 0x0 |
Maximum prefetch: | 0x0 |
Device Type: | Disk device |
Path(s): |
|
/dev/rdsk/c6t29000060220041F96257354230303052d0s2 | |
/devices/scsi_vhci/ssd@g29000060220041f96257354230303052:c,raw | |
Controller | /devices/pci@6,4000/SUNW,qlc@2/fp@0,0 |
Device Address | 2b000060220041f4,0 |
Class | primary |
State | ONLINE |
Controller | /devices/pci@6,4000/SUNW,qlc@3/fp@0,0 |
Device Address | 2b000060220041f9,0 |
Class | primary |
State | ONLINE |
Chapter 2 General Troubleshooting Procedures 7
For Internal Use Only