2-21. HIGH TEMPERATURE

1.

Drain the shortening from the frypot.

LIMIT CONTROL

 

 

(Electric Units)

 

 

(Continued)

2.

Remove control panel.

 

3.

Loosen small inside screw nut on capillary tube.

 

4.

Remove capillary bulb from bulb holder inside the frypot.

 

5.

Straighten the capillary tube.

 

6.

Remove larger outside nut that threads into pot wall.

 

7.

Remove the two screws that secure the high limit to the high

 

 

limit bracket.

 

8.

Remove the defective control from the control panel area.

 

9.

Insert new control and replace screws.

 

10.

Uncoil capillary tube, starting at control, and insert through

 

 

pot fitting.

 

 

To avoid electrical shock or other injury, run the capillary

 

 

line under and away from all electrical power wires and

 

 

terminals. The tube must NEVER be in such a position

 

 

where it could accidentally touch the electrical power

 

 

terminals.

 

11.

Carefully bend the capillary bulb and tube toward bulb holder

 

 

on heating elements.

 

12.

Slip capillary bulb into bulb holder on heating elements.

 

 

Pull excess capillary line from pot and tighten nut into frypot

 

 

wall.