Model OFE/OFG-321,322,323,324

2-17. BLOWER MOTOR

ASSEMBLY (Continued)

8.Using 3/8 inch nut driver, remove nuts securing blower to the unit. Pull blower from unit.

9.Install new blower in reverse order.

2-18. HEATING ELEMENTS

(ELECTRIC ONLY)

Heating elements are available for 208 and 230 volts. Check data plate to determine correct voltage.

Checkout:

If the shortenings temperature recovery is very slow or at a slower rate than required, this may indicate defective heating element(s). An ohmmeter will quickly indicate if the elements are shorted or open.

1. Remove electrical power supplied to the frypot to be worked on.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle, to the frypot to be worked on. Be aware the other controls will have power.

2. Remove control panel.