2-15. FILTER SWITCH

(Continued)2. Remove the control panel above the switch.

3.Label and remove the wires from the switch. With test instrument, check across the terminals of the switch with the switch in the ON position, and then in the OFF position. With the switch in the ON position, the circuit should be closed. With the switch in the OFF position, the circuit should be open. If the switch checks defective, replace it by continuing with

this

procedure.

4.With wires removed from the switch, push in on tabs on the switch and remove switch from the panel.

5.Push new switch into panel and reconnect wires.

2-16. GAS CONTROL VALVE

ASSEMBLYThe gas control valve assembly controls the flow of gas to the pilot and the main burner. The valve has two 24 volt coils, which are regulated by terminals P and M on the valve. The C terminal is the common terminal. For gas flow to the pilot, 24 VAC must be present between the P and C terminals. For gas flow to the main burner, 24 VAC must be present between the M and C terminals.

TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE, BEFORE STARTING THIS

PROCEDURE, MOVE THE MAIN POWER SWITCH

TO THE OFF POSITION. DISCONNECT THE MAIN

CIRCUIT BREAKERS AT THE CIRCUIT BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE EXPLOSION COULD RESULT.

1.Remove control panel assembly.

2.Remove wires from gas control valve.