Henny Penny OFE/OFG-322, OFE/OFG-324, OFE/OFG-321, OFE/OFG-323 manual Pilot / Ignitor, Assembly

Models: OFE/OFG-323 OFE/OFG-324 OFE/OFG-321 OFE/OFG-322

1 29
Download 29 pages 20.04 Kb
Page 9
Image 9

 

Model OFE/OFG-321,322,323,324

2-8. PILOT / IGNITOR

The Henny Penny open fryer (gas) has electronic spark ignition

ASSEMBLY

that lights a standing pilot. The gap between the spark electrode

 

and the pilot hood should be set at 1/8 of an inch.

 

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

TO AVOID PERSONAL INJURY OR PROPERTY

DAMAGE, BEFORE STARTING THIS

PROCEDURE, MOVE THE MAIN POWER SWITCH

TO THE OFF POSITION. DISCONNECT THE MAIN

CIRCUIT BREAKERS AT THE CIRCUIT BREAKER

BOX OR UNPLUG SERVICE CORD FROM WALL

RECEPTACLE. TURN OFF THE MAIN GAS

SUPPLY TO THE FRYER AND DISCONNECT AND

CAP THE MAIN SUPPLY LINE TO FRYER, OR

POSSIBLE EXPLOSION COULD RESULT.

2.Remove the control panel as discussed in Complete Control Panel Replacement Section.

3.Disconnect the pilot gas line fitting at the pilot assembly with a ½ inch wrench.

4.With a Phillips head screwdriver, remove the two screws securing the pilot assembly to the mounting bracket.

5.Remove the flame sensor wire from the flame sensor.

6.Follow the wire from the spark ignitor back to the module, and remove wire from module.

7.After removing assembly from unit, pull the flame sensor out of the bracket as discussed in section 6-7. Insert flame sensor into new pilot/ignitor assembly.

8.Reinstall the new pilot/ignitor assembly in reverse order. Be extremely careful not to cross thread the pilot gas line fitting.

203

2-9

Page 9