Model OFE/OFG-321,322,323,324

2-14. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch circuit should open, cutting off the pilot flame. This will prevent the fryer from heating while shortening is being drained from the frypot.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.The following check should be made to determine if the drain microswitch is defective.

a.Remove the two screws securing the microswitch to the drain rod valve bracket.

b.Remove wires from the switch.

c.Check for continuity across the two outside terminals of the drain switch. If the circuit is open, the drain switch is defective. The circuit should only be opened by pressing on the actuator of the drain switch.

3.Replace switch in reverse order.

2-15. FILTER SWITCH

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

203

2-13

Page 13
Image 13
Henny Penny OFE/OFG-322, OFE/OFG-324, OFE/OFG-321, OFE/OFG-323 manual Filter Switch