![](/images/new-backgrounds/1071097/710979x1.webp)
Model
2-5. POWER SWITCH
(Continued)4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel.
5.Replace with new switch, and reconnect wires to switch.
6.Replace the control panel.
REPLACEMENT the control board. If it becomes disabled,
An Ohm check can be performed also. See chart on page
1. Remove electrical power supplied to the fryer.
| To avoid electrical shock or property damage, move the |
| power switch to OFF and disconnect main circuit |
Electric | breaker, or unplug cord at wall receptacle. |
2.Drain the shortening from the frypot.
3.Remove the control panel.
Gas
4.Using a 1/2" wrench, remove the nut on the compression fitting.
5.Remove the temperature probe from the frypot.
6.Follow the appropriate instructions, on the following page, depending upon the type of fryer, gas or electric.
606 |