2-9. IGNITOR MODULE During normal operation, the ignition modules send 24 volts to the ignitors and gas control valve. If a module does not sense a pilot flame, the module starts the ignition process again. But, if a pilot light goes out for longer that 10 seconds, or it goes out 3 times within 10 seconds, the module keeps the 24 volts from reaching the gas control valve. The burners shut down.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Remove the control panel as discussed in Complete Control Panel Replacement Section.

3.Label and remove the wires at module.

4.Using a 3/8 inch nut driver, remove the keps nuts securing the module to the shroud.

5.Install new module in reverse order.

2-10. TRANSFORMER The transformer reduces voltage down to accommodate those components with low voltage.

1. Remove electrical power supplied to the unit.

To avoid electrical shock or property damage, move the POWER switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Remove the control panel as discussed in Complete Control Panel Replacement Section.

3.Squeeze on the wire connector at the I/O board assembly to disconnect the wires from the transformer.

4.Using a Phillips head screwdriver, remove the two screws securing the transformer to the shroud.

5.Install the new transformer in reverse order.