2-21. HIGH TEMPERATURE

LIMIT CONTROL (Electric Units) (Continued)

Be sure capillary bulb of high limit is located behind capillary bulb of thermostat. Both capillary bulbs

and bulb holders should be positioned as not to interfere with basket or when cleaning the frypot wall, or damage to capillary tube could result.

13.With excess capillary line pulled out, tighten smaller nut hand tight, then ¼ turn with wrench.

14.Replace front panel.

15.Refill with shortening.

2-22. AUTOLIFT1. Remove electrical power supplied to unit.

ACTUATOR (MOTOR) REPLACEMENT

(if applicable)

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Drain shortening from frypot.

3.Remove baskets and using a large, flat-head screwdriver push the clevis pin through basket hanger. Using pliers,

pull pin from assembly.

4.Remove rear cover.