Low Power Time-Out Timer

Scan the Low Power Time-Outbar code to change the time-out duration (in seconds). Then scan the time-out duration (from 0-300 seconds) from the inside back cover, and Save. Default = 120 seconds.

If the unit remains idle during the low power time-out interval, the unit goes into low power mode. Whenever the trigger is enabled, the low power time-out timer is reset.

Low Power Time-Out

Note: This time-out does not begin until the imager time-out setting has expired.

In-Stand Sensor Mode (4600r only)

Note: This feature is only applicable to the flex stand with sensor (HFSTAND5RSE) used with a 4600r, software revision 31205480-118 or higher. To determine whether you have the correct hardware and software, scan the Sensor On bar code. If it triple beeps, your device does not have this capability.

This feature tells a 4600r to sense when the scanner is removed from the stand and to begin manual triggering. When you scan Sensor On, the imager goes into manual trigger mode when it is removed from the stand. For example, if the 4600r is programmed for Presentation Mode (page 3-7),it would be in presentation mode whenever it is in the stand, and in manual trigger mode whenever it is removed from the stand. Default = Sensor Off.

Sensor On

* Sensor Off

3 - 5