new symbols as long as the trigger is pulled. When this programming selection is turned Off, the imager will only read the symbol closest to the aiming beam. Default = Off.
On
* Off
No ReadWith No Read turned On, the imager notifies you if a code cannot be read. If using a Quick*View Scan Data Window, an “NR” appears when a code cannot be read. If No Read is turned Off, the “NR” will not appear. Default = Off.
On
* Off
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,” you can edit the output message using the Data Formatter (page
Print Weight is used to adjust the way the imager reads Matrix symbols. If an imager will be seeing consistently heavily printed matrix symbols, then a print weight of 6 may improve the reading performance. For consistently light print- ing, a print weight of 2 may help. After scanning the Set Print Weight bar code, set the print weight (from
Set Print Weight
* Default