Click copy interface, the interface is shown as in Figure 6-29.

Honeywell

Parameter

Function

 

 

Bit Rate Type

There are two options: VBR and CBR.

Please note, you can set video quality in VBR mode only.

 

 

 

Quality

The value ranges from 1 to 6. Level 6 is the best video

quality.

 

 

 

 

In CBR mode, actual bit rate is limited by this value

Bit Rate

The value only affects average bit rate in VBR mode.

Please refer to recommend bit rate for the detailed

 

 

information.

 

 

Recommended

Recommended bit rate value according to the resolution

Bit Rate

and frame rate you have set.

 

 

 

Here you can set video brightness, contrast, hue, saturation

Color Setting

and gain.

The value ranges from 0 to 100. Default value is 50. See

 

 

Figure 7-27.

 

 

Cover area

Here you can privacy mask the specified video in the

monitor video.

(privacy mask)

System max supports 4 privacy mask zones.

 

 

 

 

You can enable this function so that the system overlays the

 

time information in the video window.

Time Title

The OSD transparent value is not applicable in the current

 

DVR version.

 

You can use the mouse to drag the time tilte position.

 

 

 

You can enable this function so that the system overlays

 

channel information in the video window.

Channel Title

The OSD transparent value is not applicable in current DVR

 

version.

 

You can use the mouse to drag the channel title position.

 

 

 

It is a shortcut menu button. You can copy current channel

Copy

setup to one or more channels. The interface is shown as:

 

Figure 6-29.

 

You can click the save button after you complete setup for

Save

one channel, or you can complete the whole setup and then

 

click the save button.

 

 

Refresh

Click this button to get device latest configuration

information.

 

 

 

Click copy interface, the interface is shown as in Figure 6-29.