Honeywell HSVR-16, HSVR-04 user manual Alarm Input Port, Honeywell

Models: HSVR-16 HSVR-04

1 161
Download 161 pages 47.69 Kb
Page 29
Image 29
Figure 3-1 Alarm Input and Output of HSVR-04 (Left) and HSVR-16 (Right)

Honeywell

Figure 3-1 Alarm Input and Output of HSVR-04 (Left) and HSVR-16 (Right)

Parameter

Grounding Alarm

 

 

 

Ground line

 

 

 

HSVR-04: 1, 2, 3, 4 become valid in low voltage; 5, 6, 7, 8 are not

Alarm Input

effective.

 

HSVR-16: 1-16 become valid in low voltage.

 

 

Relay Output NO C

1-NO C, 2-NO C, 3-NO C Three Normal Open activation outputs.

 

 

 

RS-485 communication port. They are used to control devices

RS-485 A/B

such as PTZ. Please parallel connect 120Ω between A/B cables if

 

there are too many PTZ decoders.

 

 

Alarm Input Port

4-ch (HSVR-04) / 16-ch (HSVR-16)grounding alarm inputs. (Normal open or Normal close type)

Please parallel connect COM end and GND end of the alarm detector (Provide external power to the alarm detector).

Please parallel connect the ground of the DVR and the ground of the alarm detector.

21

Page 29
Image 29
Honeywell user manual Alarm Input Port, Honeywell, 1 Alarm Input and Output of HSVR-04 Left and HSVR-16 Right