Figure 5-18 The Command Window

Honeywell

Under Windows Command Prompt, input ping smtp.google.com then press return.

The displayed IP address 74.125.45.25 is the SMTP server IP address.

Figure 5-18 The Command Window

Alarm

Refer to Alarm Setup and Alarm Activation on page 42.

Detect

Refer to Detect on page 36.

Pan/Tilt/Zoom

The pan/tilt/zoom setup includes the following items. Please select channel first. See Figure 5-19.

Protocol: Select corresponding PTZ protocol such as PELCOD.

Address: input corresponding PTZ address.

Baud rate: Select baud rate.

Data bit: Select data bit.

Stop bit: Select stop bit.

Parity: There are three choices: none/odd/even.

73

Page 81
Image 81
Honeywell HSVR-16, HSVR-04 user manual Alarm, Detect, Pan/Tilt/Zoom, Honeywell, 18 The Command Window