Font – Font selection. Default is disabled.
•A = OCR A
•B = OCR B
•Money = OCR Money
•MICR = Magnetic Ink Character Recognition
Direction – Decoder reads OCR fonts in any direction, but setting direction parameter correctly can increase decoding speed. Default is Left to Right.
Template – Template length must match the length of OCR string to be read. Default is dddddddd. Valid template selections are:
•a - alphanumeric character (digit or letter)
•c - check character
•d - digits from 0 to 9
•e - any character
•g - any character specified in group G
•h - any character specified in group H
•l - alphabetic letter
•r - delimits a row
•t - delimits multiple templates
All characters are transmitted as is except for the selected template.
Group G – Null terminated string defines the set of characters in group G. The default is null.
Group H – Null terminated string defines the set of characters in group H. The default is null.
Check – Enter the string constant 0123456789 for modulo10 checksums and the string constant 0123456789AB- CDEFGHIJKLMNOPQRSTUVWXYZ for modulo36 checksums.
The default is null.
OCR Template Examples1.To read a combination of 6 alpha and numeric characters use the following template: aaaaaa
8 - 23