Honeywell PDX50S60F(B,S,C)*(N,X) Exhaust Pressure Switch Replacement, to avoid personal injury

Models: PDX140S*F(BN,SX,CX) PDX440S*F(BN,SX) PDX75S70F(B,S,C)*(N,X) PDX275T*F(BN,SX,CX) PDX150S*F(BN,SX,CX) PDX65S65F(B,S,C)*(N,X) PDX265T*F(BN,SX,CX) PDX50S60F(B,S,C)*(N,X) PDX450S*F(BN,SX) PDX250T*F(BN,SX,CX)

1 40
Download 40 pages 45.12 Kb
Page 19
Image 19
Exhaust Pressure Switch

PDX Series

PDX SERVICE PROCEDURE III

Pressure Switch Testing and

Replacement

Exhaust Pressure Switch

Replacement

Step 1. Position gas control power switch to “OFF” position.

to avoid personal injury.Manual backgroundWARNING

120 volt potential exposure. Use caution

to avoid personal injury.

Step 2. Remove the three screws (Phillips screw driver) from control access cover on blower assembly and remove cover (see photo 3).

4

Step 3. Carefully remove pressure switch from blower housing (see photo 4)

Pressure Switch

5

Slide pressure switch in direction of arrow while tilting slightly away from blower housing.

6

7

Step 4. Disconnect tubing from pressure switch.

(see photo 5)

Step 5. Disconnect yellow wires from pressure switch (see photo 6)

Step 6. Reconnect wires from step 5 to new pressure switch.

Step 7. Reconnect tubing to new pressure switch.

Step 8. Carefully position pressure switch into blower housing.

Step 9. Position gas control power switch to “ON” position and verify proper heater operation.

Step 10. Replace control access cover from step 2.

Page 19

19

Page 19
Image 19
Honeywell PDX50S60F(B,S,C)*(N,X) service manual Exhaust Pressure Switch Replacement, to avoid personal injury, PDX Series