Remove blower to gain access to

PDX Series

PDX SERVICE PROCEDURE XII

Flue Baffle

Inspection and replacement

Remove blower to gain access to

flue baffle

Disconnect vent system from exhaust adapter.

Step 1. Position gas control power switch to the “OFF” position and unplug blower from wall outlet.

Step 2. Disconnect vent system from exhaust adapter on top of blower.

Step 3. Disconnect intake air piping.

Step 4. Unplug cord sets from blower. (see photo 31).

Step 5. Remove the three blower mounting screws (¼" nut driver) (see photo 31).

Step 6. Remove blower with gasket from water heater.

Step 7. Remove flue baffle from Heater (see photo 33).

Step 8. Inspect baffle for deterioration, missing restrictors.

Clean any scale or debris build up. Replace with new baffle as necessary.

31

Blower Mounting

 

 

Screws

Blower

Cord Sets

32

Step 9. Reinstall baffle into flue tube. Be sure baffle hanger tabs are inserted into notch location at the top of the flue tube (see photos 34 & 35).

Remove support

bracket

Step 10. Check Burner to insure no scale has accumulated during this operation. See burner cleaning procedure on page 15.

Step 11. Reinstall blower on water heater. Connect vent system and cords set to blower. Plug water heater into wall outlet.

Step 12. To resume operation follow the lighting instruction

located on the lighting instruction label or the lighting instruction located in the installation and operation

manual.

33

Flue Baffle

34

35

Baffle shown

installed in flue

tube notch.

Flue tube

notch

Page 33

33

Page 33
Image 33
Honeywell PDX440S*F(BN,SX) service manual Remove blower to gain access to flue baffle, PDX Series, Pdx Service Procedure