PDX SERVICE PROCEDURE VIII

PDX Series

PDX SERVICE PROCEDURE VIII

Safety Circuit Voltage Trace

Safety Circuit Voltage

Trace

NOTE: This procedure assumes a cool tank.

Safety Circuit VoltageManual backgroundWARNING

120 volt potential exposure. Use caution

making voltage checks to avoid personal injury.

24

Step 2. Remove three screws (Phillips Screw driver) from control access cover on blower and remove cover (see photo 24).

Position gas control switch to the “ON”

 

 

 

 

 

 

 

 

 

 

 

position and adjust thermostat dial to call

 

 

 

 

 

 

 

 

 

 

 

for heat, Is there 10 to 13 VAC between red

N

Is LED on gas valve flashing the

 

 

 

 

 

 

 

 

wire leading to blower temperature switch

Y

 

No voltage from gas control,

 

“heartbeat” code (alternating

 

 

and green ground wire?

 

 

 

call for technical support.

 

 

bright/dim)

 

 

 

Blower must be running during this

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage check.

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see photo 25)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Verify 120VAC to gas

 

 

 

 

 

 

 

 

 

 

 

control (see page 30)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is there 10 to 13 VAC between yellow wire

 

 

 

 

Is there continuity

 

 

Check for loose or

leading from pressure switch and green

N

 

 

 

through blower

 

Y

 

 

 

 

broken wire connection

ground wire?

 

 

 

 

temperature switch?

 

 

 

 

 

 

 

 

at switch terminals

(see photo 25)

 

 

 

 

 

(see page 21)

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Determine cause of blower

 

 

 

 

 

 

Correct igniter/

 

temperature switch activation

 

 

 

 

sensor problem.

 

 

and correct.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do you hear or can you see N the igniter sparking?

Y

Safety circuit voltage is OK.

If burner does not light, observe LED flash code on gas valve and refer to troubleshooting section on page 13

Check igniter/sensor

Y

Faulty cord set or

(see page 17)

 

gas control.

is igniter/sensor OK?

 

 

Green ground wire

 

 

25

 

 

 

 

Red wire leading to

 

 

blower temp. switch

Yellow wire leading from pressure switch

Page 29

29

Page 29
Image 29
Honeywell PDX50S60F(B,S,C)*(N,X), PDX75S70F(B,S,C)*(N,X) Safety Circuit Voltage Trace, Pdx Service Procedure, PDX Series