Honeywell PDX265T*F(BN,SX,CX), PDX450S*F(BN,SX) Over Tighten, PDX Series, Pdx Service Procedure

Models: PDX140S*F(BN,SX,CX) PDX440S*F(BN,SX) PDX75S70F(B,S,C)*(N,X) PDX275T*F(BN,SX,CX) PDX150S*F(BN,SX,CX) PDX65S65F(B,S,C)*(N,X) PDX265T*F(BN,SX,CX) PDX50S60F(B,S,C)*(N,X) PDX450S*F(BN,SX) PDX250T*F(BN,SX,CX)

1 40
Download 40 pages 45.12 Kb
Page 36
Image 36
OVER TIGHTEN

PDX Series

PDX SERVICE PROCEDURE XIII

Inner Door/Gasket Removal, Inspection

Replacement and Reinstallation

Installation of inner door with gasket (continued from page 36).

Step 10. Firmly place right side inner door flange against the left side inner door flange and secure with two ¼” drive screws from step 3c. DO NOT OVER TIGHTEN SCREWS.

Step 11. Align right side inner door to combustion chamber and verify the fastener holes of the combustion chamber are aligned with the right side inner door slotted opening. Verify seal integrity around

combustion

opening. Secure right side inner door using 1/4” hex drive screws from step 3b. DO NOT

OVER TIGHTEN

SCREWS. Verify both left and right sides of the inner door are properly positioned and

sealed against the combustion chamber

Verify threaded hole alignment with slotted openings in inner door.

Step 12. Replace outer jacket burner access door.

Step 13. To resume operation follow the instructions located on the lighting instruction label or the lighting instructions located in the installation and operation manual.

Page 36

36

Page 36
Image 36
Honeywell PDX265T*F(BN,SX,CX), PDX75S70F(B,S,C)*(N,X), PDX450S*F(BN,SX) Over Tighten, PDX Series, Pdx Service Procedure