PDX Series
Troubleshooting
| LED Status |
| Control Status |
| Probable Cause |
| Service | |||||||
|
|
|
|
|
|
|
| |||||||
|
|
| Procedure | |||||||||||
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| 1. Unstable pilot. | 1. Page 15 | |||||||
Failed to light pilot. | 2. Pilot tube blocked or restricted. | |||||||||||||
|
|
|
|
| ||||||||||
second pause | System auto resets. | 3. Oxidation build up on pilot electrode. | ||||||||||||
|
|
|
|
|
| 4. Wire damage to pilot assembly or bad |
|
|
|
|
| |||
|
|
|
|
|
| connection at gas valve. |
|
|
|
|
| |||
|
|
| Pressure switch | 1. Vent blockage or improper vent configuration. | 1. Check vent or vent tables. | |||||||||
|
|
| 2. Pressure switch tubing kinked or blocked. | |||||||||||
|
|
| or blower temp | 2 & 3 Page 18 | ||||||||||
|
|
| 3. Faulty pressure switch. | |||||||||||
|
|
| switch opened | 4. Refer to venting section of | ||||||||||
4. Vent termination being affected by wind | ||||||||||||||
during burner | installation manual | |||||||||||||
second pause | 5. Blower not spinning up to speed. | 5. Page 20 | ||||||||||||
operation. | ||||||||||||||
|
|
| 6. Blower temp or exhaust temp too high | 6 & 7 Page 22 | ||||||||||
|
|
| System auto | 8. Refer to installation | ||||||||||
|
|
| 7. Faulty blower temperature switch. | |||||||||||
|
|
| resets. | manual. | ||||||||||
|
|
| 8. Insufficient combustion air. | |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 1. Unstable pilot. |
|
|
|
|
| |||
|
|
| Pilot flame | 2. Pilot tube blocked or restricted. | 1. Page 15 | |||||||||
|
|
| 3. Oxidation build up on pilot electrode. |
|
|
|
|
| ||||||
extinguished. | ||||||||||||||
4. Wire damage to pilot assembly or bad | ||||||||||||||
second pause | System auto |
|
|
|
|
| ||||||||
connection at gas valve. | 5. Refer to installation manual | |||||||||||||
|
|
| resets. | |||||||||||
|
|
| 5. Insufficient combustion air. |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 6. Gas pressure is out of specification. |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| ||||
pilot flame | Pilot valve stuck in open position. | Replace gas control, | ||||||||||||
sensed. | ||||||||||||||
second pause | page 26 | |||||||||||||
System auto |
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| resets. |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
| WARNING: EXPLOSION HAZARD |
|
|
|
|
| |||
|
|
|
|
|
| * Indicates gasoline vapors were detected at potentially |
|
|
|
|
| |||
|
|
| Flammable Vapor | explosive levels. |
|
|
|
|
| |||||
Seven flash, three second | * Verify no gasoline vapors are still present | Page 28 | ||||||||||||
pause | Sensor fault | * Reset the control by cycling power to the appliance or | ||||||||||||
|
|
| detected | by cycling the ON/OFF switch. |
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
| * Replace the Flammable Vapors Sensor element if a |
|
|
|
|
| |||
|
|
|
|
|
| gasoline spill event occurred. |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Flammable Vapor | * Verify Flammable Vapor Sensor (FVS) resistance is |
|
|
|
|
| ||||||||
Sensor out of | not below 25 K Ohms. | Page 28 | ||||||||||||
second pause | * Check wiring to FVS and insure it is not shorted. | |||||||||||||
specification. |
|
|
|
|
| |||||||||
|
|
| * Replace control if everything above checks out OK. |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Thermal well | 1. Damage to thermal well wire. | Page 24 | |||||||||
|
|
| sensor damaged | |||||||||||
|
|
| 2. Thermal well sensor resistance out of range. | |||||||||||
or unplugged |
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
| |||||||
second pause | Gas valve | 1. Control needs to be reset. | 1. Interrupt power supply | |||||||||||
|
|
| electronics fault | 2. Replace gas control, | ||||||||||
|
|
| 2. Control is wet or physically damaged. | |||||||||||
|
|
| detected | page 26 | ||||||||||
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Gas valve fault | 1. Control needs to be reset. | 1. Interrupt power supply | ||||||||||||
second pause | detected. | 2. Control is wet or physically damaged. | 2. Replace gas control, | |||||||||||
page 26 | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Page 14
14