Honeywell PDX275T*F(BN,SX,CX) Flammable Vapor Device Testing, PDX Series, Pdx Service Procedure

Models: PDX140S*F(BN,SX,CX) PDX440S*F(BN,SX) PDX75S70F(B,S,C)*(N,X) PDX275T*F(BN,SX,CX) PDX150S*F(BN,SX,CX) PDX65S65F(B,S,C)*(N,X) PDX265T*F(BN,SX,CX) PDX50S60F(B,S,C)*(N,X) PDX450S*F(BN,SX) PDX250T*F(BN,SX,CX)

1 40
Download 40 pages 45.12 Kb
Page 28
Image 28
Flammable Vapors Sensor Testing

PDX Series

PDX SERVICE PROCEDURE VII

Flammable Vapors Sensor Testing

Flammable Vapor Device Testing

Step 1. Position power switch on gas control to the “OFF” position.

Step 2. Disconnect flammable vapor sensor from gas control.

Step 3. Using a multi-meter set to the ohms setting check resistance of flammable vapor sensor. (see caution below)

Resistance must be within 3,000 ohms and 48,000 ohms. If outside of this range replace flammable vapor sensor.

Multi-meter set to Flammable Vapor Device Testing ohms setting

Electronic

“pin type”

Meter Probes

Flammable Vapor

Sensor

Manual backgroundManual backgroundManual backgroundManual background CAUTION

DO NOT use standard multimeter probes for this test. Doing so will damage connector. Use special electronic “pin type” probes or small diameter wire pins inserted into connector.

Flammable Vapor Sensor